The below is an excerpt from TABLE MOUNTAIN NATIONAL PARK FIRE MANAGEMENT PLAN originally published including https://www.sanparks.org/. 

"Minimum width of 15 meters, however this could be extended depending on the gradient of a location, wind conditions, combustibility of the fuel material, as well as flame height conditions." ​

Read the full article here: 

Full 2004 SANParks Report here.

Full 2017 Santam Report on "Mega Fires".

The firebreak should be wide enough and long enough to have a reasonable chance of preventing a veldfire from spreading.

Check that the firebreak does not cause soil erosion.  

Ensure the firebreak is free from flammable materials.

Maintain vegetation height as low as possible, alternatively completely removing vegetation in the firebreak area.  

Clear out the combustible material derived from creating the firebreak so that it ​cannot be used as fuel in a fire.  

On the slopes of Table Mountain, firebreaks are created by brush-cutting versus controlled burning in some instances, especially in fire season. This is due to the fire in this area having run-away properties when considering the type of unique (and dry) vegetation in this mountainous range.

Firebreaks should be done in consultation with the local Fire Protection Association and the Fire Services closest to you. They will be able to provide the best advice for your unique ecological area.  
In general, unless authorised by the Fire Services explicitly, no fires are allowed on Table Mountain.

Refer to Table 11: Relationship between the mean flame length in metres, fire hazard class and controllability of a veldfire as derived from Teie (2003).

Refer to: Figure 9: An example of the basic command structure for large veldfires from TABLE MOUNTAIN NATIONAL PARK FIRE MANAGEMENT PLAN.

Latest News

  • FPASA September 2026 Magazine

    Our September 2026 Magazine is Here!

    We’re pleased to announce that the 3rd Quarter Edition of the FPASA Magazine – September 2026 is now available to read.

    This latest edition brings together industry news, insights and information from across the fire protection and fire safety sector.

    A special thank you to all our advertisers who supported this edition. Your continued support helps us share valuable information with the fire protection community and contributes to the ongoing work of the Fire Protection Association of Southern Africa.

    📖 Read the September 2026 edition now and stay informed, connected and up to date with FPASA.

    Thank you to our contributors, advertisers, members and readers for your continued support.

  • Spring Training Special 2026

  • 📢 Telephone Service Interruption

    Dear Valued Members and Stakeholders,

    Please be advised that we are currently experiencing a technical issue with our telephone lines. As a result, we are unable to make or receive calls at this time.

    Our IT team is actively investigating the matter and working to restore services as quickly as possible.

    For any urgent enquiries, please contact us via email:

    📧 This email address is being protected from spambots. You need JavaScript enabled to view it.
    📧 This email address is being protected from spambots. You need JavaScript enabled to view it.

    We apologize for the inconvenience and appreciate your patience and understanding.

    FPASA Team

Website Accreditation Banner 5